Abstract

The paper compares the simulation results concerning two types of dangerous failures of the autoclave filled with hazardous media subjected elevated pressure (420 MPa). A non-stationary, 2-D axisymmetric, physical-numerical model of the system is proposed. It is assumed that it is possible to break off the mandrel of the autoclave or the whole cork assembly. In both cases the broken off structural elements are driven by the leaking medium and the leakage of the high pressure liquid into the environment is present. It is accompanied by the formation of the shock wave propagating in the air. The maximum speed and kinetic energy of the broken off elements has been determined, along with the characteristics of the shock wave. On the basis of parameters characterizing the shock wave generated by the discharged liquid, a TNT equivalent was determined.
Author Marcin Bajkowski (FPE / IMP)
Marcin Bajkowski,,
- The Institute of Mechanics and Printing
, Marek Radomski (FPE / IMP)
Marek Radomski,,
- The Institute of Mechanics and Printing
, Karol Jach
Karol Jach,,
-
, Robert Świerczyński
Robert Świerczyński,,
-
Journal seriesMachine Dynamics Research, ISSN 2080-9948, (B 14 pkt)
Issue year2015
VolVol 39
No3
Pages103-118
Publication size in sheets0.75
Keywords in Englishautoclave; pressure vessel; high pressure; shockwave; propagation
URL http://mdr.simr.pw.edu.pl/index.php/MDR/article/view/129/128
Languageen angielski , en angielski
Score (nominal)14
ScoreMinisterial score = 14.0, 28-11-2017, ArticleFromJournal
Ministerial score (2013-2016) = 14.0, 28-11-2017, ArticleFromJournal
Citation count*
Cite
Share Share

Get link to the record


* presented citation count is obtained through Internet information analysis and it is close to the number calculated by the Publish or Perish system.
Back