Flexible humidity sensors with polymer sorption layer

Bartosz Dzikowski , Adrian Zduńczyk , Jerzy Weremczuk , Grzegorz Owczarek , Wojciech Fabianowski

Abstract

This paper presents humidity sorption sensors with eight different polymer coatings. After the introduction of sensor construction, a presentation of tested sorption laters and measurement system is provided. Finally, the results are presented and discussed as well as validation tests are described. Two most suitable coatings are chosen.
Author Bartosz Dzikowski (FEIT / PE)
Bartosz Dzikowski,,
- The Institute of Electronic Systems
, Adrian Zduńczyk - [Warsaw University of Technology (PW)]
Adrian Zduńczyk,,
-
- Politechnika Warszawska
, Jerzy Weremczuk (FEIT / PE)
Jerzy Weremczuk,,
- The Institute of Electronic Systems
, Grzegorz Owczarek - [Centralny Instytut Ochrony Pracy - Państwowy Instytut Badawczy (CIOP PIB)]
Grzegorz Owczarek,,
-
- Centralny Instytut Ochrony Pracy - Państwowy Instytut Badawczy
, Wojciech Fabianowski (FC / CPCT)
Wojciech Fabianowski,,
- Chair Of Polymer Chemistry And Technology
Pages101610Z-1-101610Z-8
Publication size in sheets0.5
Book Jasiński Piotr (eds.): Proc. SPIE. 10161, 14th International Conference on Optical and Electronic Sensors , vol. 10161, 2016, P.O. Box 10, Bellingham, Washington 98227-0010 USA , SPIE , ISBN 9781510607804, [9781510607811 (electronic)], 235 p., DOI:10.1117/12.2265889
Keywords in Englishhumidity sensors, polymers, flexible sensors, wearable sensors
DOIDOI:10.1117/12.2245044
URL http://dx.doi.org/10.1117/12.2245044
Languageen angielski
File
Dzikowski_101610Z.pdf 840.73 KB
Score (nominal)0
Publication indicators WoS Citations = 0; Scopus Citations = 1; GS Citations = 2.0
Citation count*2 (2020-08-30)
Cite
Share Share

Get link to the record


* presented citation count is obtained through Internet information analysis and it is close to the number calculated by the Publish or Perish system.