Wymiar fraktalny wybranych struktur złączy spawanych ze stali 15HM

Jarosław Grześ

Abstract

The paper presents the results of fractal dimension measurements. The selected cross-sections structures of 15HM steel welded joint have been the subject of investigations. The computer image processing techniques have been applied to prepare images of structures for measurements. Both box (BCD) and line (LCD) counting dimension algorithms have been used to obtain the fractal dimension of analyzed structures.
Author Jarosław Grześ ITW
Jarosław Grześ,,
- The Institute of Manufacturing Processes
Journal seriesPrzegląd Spawalnictwa, ISSN 0033-2364, e-ISSN 2449-7959
Issue year2016
VolVol. 88
No6/2016
Pages36-42
Publication size in sheets0.5
Keywords in Polishwymiar fraktalny, struktura, strefa wpływu ciepła, spawanie
Keywords in Englishfractal dimension, structure, heat affected zone, welding
Abstract in PolishPrzedmiotem przedstawionych badań były struktury złącza spawanego ze stali 15HM. Głównym celem badań było określenie wymiaru fraktalnego wybranych struktur spoiny i strefy wpływu ciepła. W tym celu zastosowano cyfrowe przetwarzanie i analizę obrazu. Dla badanych struktur określono wymiar fraktalny pudełkowy i liniowy, wykorzystując odpowiednio metodę ”Box Counting Dimension” (BCD) oraz jej modyfikację „Line Counting Dimension” (LCD).
Languagepl polski
Score (nominal)9
ScoreMinisterial score = 9.0, 28-11-2017, ArticleFromJournal
Ministerial score (2013-2016) = 9.0, 28-11-2017, ArticleFromJournal
Citation count*0
Cite
Share Share



* presented citation count is obtained through Internet information analysis and it is close to the number calculated by the Publish or Perish system.
Back